Solinst 2-wire signals are converted to SDI-12 signals by the Solinst SDI-12 Interface Cable. One end of this cable has three wires which connect to an SDI-12 datalogger. These wires are colour-coded according to Table 1-1. The other end of the cable terminates in a Direct Read connection. This connects to the top of a Direct Read Cable for connection to a Solinst Levelogger. The Solinst Levelogger has a self-contained battery and does not use +12V DC power. The SDI-12 Interface Cable circuitry requires the 12V connection. The current draw is nominally around 15 - 25 mA at 12V DC. Idle current draw is ~0.1 mA.
Wire Colour | SDI-12 Function | Connection |
---|---|---|
Red | 12 Volt Line | +12V DC at SDI-12 Datalogger |
Black | Ground Line | Ground at SDI-12 Datalogger |
White | Serial Data Line | SDI-12 Data at SDI-12 Datalogger |
Table 1-1 SDI-12 Interface Cable Wire Definitions
The communication settings for the Solinst SDI-12 Interface Cable hardware comply with the SDI-12 standard at 1200 baud, 1 start bit, 7 data bits, 1 parity bit (even parity), and 1 stop bit.
Technical Specifications | |
---|---|
Standard Compliance | SDI-12 Standard, Version 1.3, July 18, 2005 |
+12V Input | 9.6V-16.0V |
Average Current Draw While Taking Readings | 15-25 mA |
Idle Current Draw | ~0.1 mA |
Direct Read Cable – Max Length | 1500 ft |
SDI-12 Cable Length – Max Length | 200 ft |
Environmental | IP-65 |
Table 1-2 SDI-12 Technical Specifications